Aircraft Ignition Systems: Magnetos, Spark Plugs and the Powerplant Exam
The ignition questions are the most mechanical part of the Powerplant test: a magnet that turns, a set of points that opens at exactly the right instant, and a plug that either fires cleanly or fouls. Learn the sequence once and the questions stop being memory work.
SkyLicense Team
FAA A&P exam preparation specialists: helping mechanics earn their Airframe & Powerplant certificate since 2025
What the Powerplant Test Asks About Ignition
Ignition and starting systems sit inside the Powerplant section of the Aviation Mechanic ACS, and the questions there are unusually predictable: how a magneto makes its own spark, how that spark is timed to the crankshaft, why the engine carries two magnetos, what the ignition switch does, why plugs foul, and how a mechanic decides at the run-up whether the system is airworthy. These items are cheap marks if you understand the machine. Our breakdown of the A&P exam structure is the place to start if you have not read it.
A Magneto Is a Self-Contained Generator of Sparks
A magneto needs no battery and no external power. A permanent magnet rotor turns inside a soft-iron core carrying two windings: a primary of relatively few turns of heavy wire and a secondary of many thousands of turns of fine wire. Rotation alone changes the flux linking those windings, which is the whole principle of the device.
While the breaker points are closed, primary current builds a magnetic field around the core. When a cam opens the points, that current is interrupted and the field collapses across the secondary, where the large turns ratio lifts the voltage high enough to jump the plug gap. The distributor rotor, driven at half crankshaft speed, hands the pulse to the correct cylinder in firing order.
The capacitor, still called a condenser on many parts diagrams, absorbs the arc that would burn the points and forms an oscillating circuit with the primary that makes the field collapse faster, which raises secondary voltage. A failed capacitor shows up as pitted points and a weak spark.
The E-Gap Is Where the Points Open
Timing starts with rotor position, not with the switch. In a rotating-magnet magneto the points must open at the E-gap, the rotor position where flux change through the core is at its maximum. Open them anywhere else and secondary voltage falls off, giving a weak spark that may not fire under compression.
That setting is the magneto's internal timing, set on the bench with a buzz box or timing light rather than by eye. It is separate from engine timing: internal timing sets when the spark leaves the magneto, engine timing sets where the piston is when it arrives.
The Impulse Coupling: A Starting Aid, Not a Timing Change
At cranking speed a magneto turns far too slowly to generate a hot spark. The impulse coupling is a spring-loaded device on the magneto drive that latches during cranking, winds the rotor back, then releases it so the magnet snaps through the E-gap at high speed. The spark is hot and, just as important, it is retarded to arrive near top dead centre instead of kicking back against the starter.
Above starting speed, flyweights disengage the latch and the magneto returns to normal advanced timing. Two exam outcomes follow: the coupling retards the spark for starting only, and a sheared coupling gives an engine that will not start.
Two Magnetos, One Switch, and the Hot-Mag Hazard
Every cylinder carries two plugs and each magneto fires one plug per cylinder. That is the redundancy: lose a magneto and the engine keeps running on the remaining plug, with slower flame travel, less power, higher exhaust gas temperature and worse fuel consumption.
The ignition switch is the part candidates most often get backwards. It does not switch power on to the magnetos, because a magneto makes its own. It switches them off. ON leaves each primary circuit isolated so the points can work; OFF grounds it through the P-lead, killing the spark. LEFT or RIGHT grounds the magneto you are not testing.
That design creates the hot mag. A broken P-lead or a corroded ground can leave a magneto live with the key removed, and a live magneto fires every time the engine turns. Treat every propeller as capable of firing, ground the magnetos before you turn an engine by hand, and never test ignition by flicking the switch on a running engine.
Spark Plugs: Massive Electrode, Fine Wire, and Fouling
Two families cover almost everything you will be asked. The massive-electrode plug is the familiar two-electrode design with a nickel-alloy centre electrode, usually shielded with a resistor to suppress radio interference; it is cheap, easy to re-gap, and standard on normally aspirated engines. The fine-wire plug puts an iridium or platinum centre electrode inside small wire electrodes, lasts much longer, resists fouling better, and suits engines where fouling risk is high.
Heat range matters as much as the part number: too hot and the electrode glows, inviting preignition; too cold and deposits bridge the gap. Lead fouling from the tetraethyl lead in 100LL avgas leaves pale, fluffy deposits. Carbon fouling is sooty black, the signature of a rich idle mixture or long ground runs. Oil fouling is wet and dark and points at worn rings or valve guides rather than at the plug. Service plugs on the manufacturer's interval: clean, gap, pressure-test, rotate positions so the hottest and coldest spots share wear, and torque to the specified value.
Engine Timing and the Run-Up Magneto Drop Check
Engine timing is the relationship between the spark and piston position, set to the advance the engine manufacturer publishes, typically in the low twenties of degrees before top dead centre on horizontally opposed engines. Re-check magneto-to-engine timing whenever you fit a magneto or change points.
The practical test of the system is the magneto drop check at the run-up. The widely quoted limits are a maximum drop of 175 RPM and a maximum difference of 50 RPM between magnetos; both come from the aircraft POH or the manufacturer's data, so quote the source rather than treating them as universal. Here is the arithmetic at 1,700 RPM.
- Baseline: 1,700 RPM on BOTH.
- Left magneto: settles at 1,550, so the drop is 1,700 minus 1,550, which is 150 RPM, inside the 175 RPM limit.
- Right magneto: settles at 1,585, so the drop is 1,700 minus 1,585, which is 115 RPM, also inside.
- Difference: 150 minus 115 is 35 RPM, inside the 50 RPM limit. This check passes.
Now the counter-example. Had the left magneto settled at 1,490 the drop would be 210 RPM, over the limit and a failure on that magneto alone. Had both drops been legal but one 160 and the other 95, the 65 RPM difference would fail the check even though each looked acceptable by itself. A magneto that shows no drop at all is worse: the engine was already running on the other one, which points at a dead magneto, a grounded P-lead or a harness fault.
Inspection Intervals and How the ACS Words the Task
Manufacturers call for an internal magneto inspection at a stated hour interval, commonly 500 hours, when the points, capacitor, distributor block, gears and internal timing are examined and the E-gap reset. Plugs are serviced and rotated on the manufacturer's schedule, usually tied to the annual or 100-hour inspection scope. Learn the requirement in words rather than as a number: the manufacturer's interval, the timing figure from the maintenance manual, and the POH drop limits.
The ACS words the ignition items as tasks: identify components, explain magneto operation and timing, inspect and service plugs, and determine the cause of a malfunction from its symptoms. The last one discriminates, so learn the paired symptoms: roughness that clears when one magneto is grounded, or an engine that will not start after a magneto change.
Work the same material in question form with our Powerplant written test FAQ, and read the aircraft electrical systems FAQ for the charging and starting circuits that share the page in most handbooks.
📥 Get the free printable study checklist: a 30-day FAA A&P exam prep plan with daily tasks covering 14 CFR Parts 43 and 65, AC 43.13-1B, ADs, and full-length exam simulations.
Download Free 30-Day Checklist →